Cofnij do: Elektryka
Rozłączniki, wyłączniki - strona 46
LV429014
This is a 3 poles basic frame for Compact NSX100B. Compact NSX is designed to optimize space and breaking capacity for all standard and specific applications. This basic frame comes without trip unit, and is compatible with any type of trip unit which has to be ordered separately The breaking capacity Icu is 25kA at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz (limited...
SCHNEIDER ELECTRIC
LV429015
This is a 4 poles basic frame for Compact NSX100B. Compact NSX is designed to optimize space and breaking capacity for all standard and specific applications. This basic frame comes without trip unit, and is compatible with any type of trip unit which has to be ordered separately The breaking capacity Icu is 25kA at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz (limited...
SCHNEIDER ELECTRIC
LV429018
This is a 3 poles basic frame for Compact NSX100S. Compact NSX is designed to optimize space and breaking capacity for all standard and specific applications. This basic frame comes without trip unit, and is compatible with any type of trip unit which has to be ordered separately The breaking capacity Icu is 100kA at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz (limited...
SCHNEIDER ELECTRIC
LV429019
This is a 4 poles basic frame for Compact NSX100S. Compact NSX is designed to optimize space and breaking capacity for all standard and specific applications. This basic frame comes without trip unit, and is compatible with any type of trip unit which has to be ordered separately The breaking capacity Icu is 100kA at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz (limited...
SCHNEIDER ELECTRIC
LV429030
This TM100D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated...
SCHNEIDER ELECTRIC
LV429031
This TM80D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 80A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated...
SCHNEIDER ELECTRIC
LV429032
This TM63D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 63A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated...
SCHNEIDER ELECTRIC
LV429033
This TM50D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 50A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with...
SCHNEIDER ELECTRIC
LV429034
This TM40D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 40A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with...
SCHNEIDER ELECTRIC
LV429035
This TM32D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 32A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with...
SCHNEIDER ELECTRIC
LV429036
This TM25D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100 circuit breakers. This 25A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with...
SCHNEIDER ELECTRIC
LV429037
This TM16D is a 3 poles 3d thermal-magnetic trip unit used on Compact NSX 100 circuit breakers. This 16A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with...
SCHNEIDER ELECTRIC
LV429040
This TM100D is a 4 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 100A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated...
SCHNEIDER ELECTRIC
LV429041
This TM80D is a 4 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 80A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated...
SCHNEIDER ELECTRIC
LV429042
This TM63D is a 4 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160/250 circuit breakers. This 63A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated...
SCHNEIDER ELECTRIC
LV429043
This TM50D is a 4 poles 3d thermal-magnetic trip unit used on Compact NSX 100/160 circuit breakers. This 50A rating thermal-magnetic trip unit is an optimum choice for all distribution applications. It embeds an adjustable thermal overload protection and a fixed magnetic protection against short-circuits. This product is part of our EcoStruxure Power architecture if associated with...
SCHNEIDER ELECTRIC