LV430520
This Micrologic 2.2 M is a 3 poles 3d electronic trip unit used on Compact NSX 160/250 circuit breakers. This 150A rating electronic trip unit is an optimum choice for motor protection applications. It embeds an adjustable long time protection against overloads. It provides also an adjustable short-time protection and a fixed instantaneous protection against short-circuits. Micrologic...
SCHNEIDER ELECTRIC
LV430521
This Micrologic 6.2 E-M (Energy) is a 3 poles 3d electronic trip unit used on Compact NSX 160/250 circuit breakers. This 150A rating electronic trip unit is an optimum choice for motor protection applications. It embeds an adjustable long time protection against overloads. It provides also an adjustable short-time protection and a fixed instantaneous protection against short-circuits...
SCHNEIDER ELECTRIC
LV430554
These are snap-in nuts for Compact NSX160/250 standard power terminal connections. It is used for M8 screws. They are sold by set of 12 parts.
SCHNEIDER ELECTRIC
LV430557
This is an additional current transformer module of 150A rating for 3 poles Compact NSX 160/250 devices. This module enables direct connection of a measurement device such as an ammeter. The module is installed directly on the downstream circuit breaker power terminals. The current at the secondary winding is 5A. The power consumption accuracy is 3VA (class 3). There is a class...
SCHNEIDER ELECTRIC
LV430558
This is an additional current transformer module of 150A rating for 4 poles Compact NSX 160/250 devices. This module enables direct connection of a measurement device such as an ammeter. The module is installed directly on the downstream circuit breaker power terminals. The current at the secondary winding is 5A. The power consumption accuracy is 3VA (class 3). There is a class...
SCHNEIDER ELECTRIC
LV430561
This is an additional current transformer module with voltage measurement output of 150A rating for 3 poles Compact NSX 160 devices. This module enables direct connection of a measurement device such as an ammeter. The module is installed directly on the downstream circuit breaker power terminals. The current at the secondary winding is 5A. The rated voltage Ue is 530VAC 50/60Hz...
SCHNEIDER ELECTRIC
LV430562
This is a current transformer module with voltage measurement output for 4 poles Compact NSX 100/160/250. This module enables direct connection of a digital measurement device such as a Power Meter PM700 or PM800. The current rating is 150A and the operational voltage is 530 VAC 50/60 Hz. The module is installed directly on the downstream circuit breaker terminals. The current at...
SCHNEIDER ELECTRIC
LV430563
It is an external neutral current transformer (ENCT) for Compact NSX160/250 equipped with Micrologic 5/6 trip unit. With 3P devices, the distributed neutral of the installation can be protected by installing this external sensor. The sensor rated current is from 150 A to 250 A. The ENCT must be connected to the Micrologic trip unit by a shielded twisted pair. The wiring maximum...
SCHNEIDER ELECTRIC
LV430619
This Compact NSX160NA is a complete 2 poles switch disconnector. It is used to control and isolate electrical distribution circuits and it requires an upstream protection. The operational current is 160A at 415VAC 50/60Hz for AC22A and AC23A utilisation categories. The operational voltage is 690VAC 50/60Hz. It comes with a variety of optional functions and accessories common with...
SCHNEIDER ELECTRIC
LV430629
This Compact NSX160NA is a complete 3 poles switch disconnector. It is used to control and isolate electrical distribution circuits and it requires an upstream protection. The operational current is 160A at 415VAC 50/60Hz for AC22A and AC23A utilization categories. The operational voltage is 690VAC 50/60Hz. It comes with a variety of optional functions and accessories common with...
SCHNEIDER ELECTRIC
LV430630
This Compact NSX160F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 160A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable...
SCHNEIDER ELECTRIC
LV430631
This Compact NSX160F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 125A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable...
SCHNEIDER ELECTRIC
LV430632
This Compact NSX160F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 100A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable...
SCHNEIDER ELECTRIC
LV430639
This Compact NSX160NA is a complete 4 poles switch disconnector. It is used to control and isolate electrical distribution circuits and it requires an upstream protection. The operational current is 160A at 415VAC 50/60Hz for AC22A and AC23A utilization categories. The operational voltage is 690VAC 50/60Hz. It comes with a variety of optional functions and accessories common with...
SCHNEIDER ELECTRIC
LV430640
This Compact NSX160F is a complete 4P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 160A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable...
SCHNEIDER ELECTRIC
LV430641
This Compact NSX160F is a complete 4P 3d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 125A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable...